Concentricity drives zero-backlash coupling life.
Evidence: Rigid bellows and disc couplings tolerate almost zero misalignment (often <0.05mm parallel). Misalignment induces alternating bending stresses that fatigue the flex elements rapidly.
Action: Specify a concentricity tolerance of Ø 0.03 mm (0.0012") between the motor pilot bore and the actuator pilot bore on the drawing. If the bracket cannot hold this, switch to an elastomeric jaw coupling.